№ files_lp_4_process_3_098035
File format: docx
Character count: 5738
File size: 22 KB
This document provides technical specifications for static fire dampers, including installation requirements, materials, and performance ratings based on industry standards.
Year:
2023
Region / City:
Chattanooga, TN
Topic:
Fire Dampers, HVAC Systems
Document Type:
Product Specification
Organization:
United Enertech
Author:
Not specified
Target Audience:
Engineers, Contractors
Effective Period:
Not specified
Approval Date:
Not specified
Amendment Date:
Not specified
Price: 8 / 10 USD
The file will be delivered to the email address provided at checkout within 12 hours.
The file will be delivered to the email address provided at checkout within 12 hours.
Don’t have cryptocurrency yet?
You can still complete your purchase in a few minutes:- Buy Crypto in a trusted app (Coinbase, Kraken, Cash App or any similar service).
- In the app, tap Send.
- Select network, paste our wallet address.
- Send the exact amount shown above.
The final amount may vary slightly depending on the payment method.
The file will be sent to the email address provided at checkout within 24 hours.
The product description is provided for reference. Actual content and formatting may differ slightly.
Year:
2015
Region / City:
Kansas City, Missouri
Subject:
HVAC systems, dampers, air control devices
Document Type:
Product specification
Organization / Institution:
Ruskin Company
Author:
Ruskin Company
Target Audience:
Specifiers, engineers, and HVAC system designers
Period of validity:
Not specified
Approval Date:
Not specified
Date of amendments:
Not specified
Year:
2015
Region / City:
Kansas City, Missouri
Theme:
HVAC Systems
Document Type:
Product Specification
Organization / Institution:
Ruskin Company
Author:
Ruskin Company
Target Audience:
Specifiers, HVAC engineers
Period of Validity:
Not specified
Approval Date:
Not specified
Amendment Date:
Not specified
Note:
Year
Model:
CB-601
Product Name:
Backdraft Dampers
Division:
23 – Heating, Ventilation, and Air Conditioning (HVAC)
Section Number:
233313 (Previously 15820)
Type of Operation:
Gravity operated or actuator operated
Manufacturer:
United Enertech
Manufacturer Address:
3005 South Hickory Street, Chattanooga, TN 37407
Manufacturer Phone:
(423) 698-7715
Standards Referenced:
AMCA 500-D; AMCA 511
Maximum Velocity:
4000 fpm (20.4 m/s)
Temperature Range:
-40°F to 200°F (-40°C to 93°C)
Differential Pressure Rating:
4.0 in. wg. (99.6 kPa)
Leakage Rating:
12 cfm/ft² @ 1 in. wg.
Frame Material:
Extruded aluminum
Blade Material:
Extruded aluminum
Seal Material:
Extruded vinyl
Mounting Orientation:
Vertical or horizontal
Warranty Period:
5 years
Factory Testing:
Cycle tested for proper operation
Applicable Systems:
HVAC duct systems
Related Sections:
233100 – HVAC Ducts and Casings; 230913.13 – Actuators and Operators
Model:
FD-B Static Curtain Fire Dampers
Division:
23 – Heating, Ventilation, and Air Conditioning (HVAC)
Section Number:
233313 (Previously 15820)
Document Type:
Product Specification Guide
Manufacturer:
United Enertech
Manufacturer Address:
3005 South Hickory Street, Chattanooga, TN 37407
Applicable Standards:
UL 555; NFPA 90A; NFPA 90B; NFPA 101; AMCA 500-D; AMCA 511; IBC; CSFM
Fire Rating Options:
1½ hours; 3 hours
Release Temperature Options:
165 ºF (74 ºC); 212 ºF (100 ºC)
Mounting Orientation:
Vertical and/or Horizontal
Warranty Period:
5 years
Application:
Static HVAC duct penetrations through fire-resistance-rated barriers
Execution Requirements:
Examination, Installation, Handling, Delivery, Storage
Division:
23 – Heating, Ventilation, and Air Conditioning (HVAC)
Section:
233313 (Previously 15820)
Product Name:
Backdraft Dampers
Model:
CB-600
Manufacturer:
United Enertech
Manufacturer Address:
3005 South Hickory Street, Chattanooga, TN 37407
Standards Referenced:
Air Movement and Control Association (AMCA 500-D, AMCA 511)
Applicable Systems:
HVAC systems up to 2800 fpm (14.2 m/s)
Temperature Range:
-40°F to 200°F (-40°C to 93°C)
Maximum Velocity:
2800 fpm (14.2 m/s)
Differential Pressure Rating:
3.0 in. wg. (0.74 kPa)
Leakage Rating:
8.7 cfm/ft² @ 1 in. wg.
Construction Material:
Extruded aluminum frame and blades
Blade Operation:
Gravity operated or actuator operated
Mounting Orientation:
Vertical or horizontal (upblast or downblast)
Actuator Options:
Electric 24VAC, 120VAC, 230VAC with open or closed fail position
Warranty Period:
5 years
Testing Requirements:
Pressure drop and leakage ratings in accordance with AMCA 500-D
Quality Control:
Factory cycled prior to shipment
Year:
NA
Region / City:
NA
Topic:
Seismic engineering, high-rise buildings
Document Type:
Research project report
Institution:
NA
Author:
NA
Target Audience:
Engineers, researchers in structural and seismic engineering
Period of validity:
NA
Approval Date:
NA
Date of revisions:
NA
Context:
Research on seismic protection systems for high-rise buildings using LRB isolators and VE dampers.
Document Type:
Product Specification Guide
Product Name:
Model FSD-200 Series Combination Fire Smoke Dampers
Manufacturer:
Greenheck India Private Limited
Address:
Off No. 541-542, Tower B3, Spaze I-Tech Park, Sector-49, Sohna Road, Gurgaon – 122018, Haryana, India
Facility Service Subgroup:
Division 23 HVAC (Previously Division 15)
Applicable Standards:
UL 555 (Seventh Edition); UL 555S (Fourth Edition); AMCA 500-D; AMCA 511; NFPA 80; NFPA 90A; NFPA 92A; NFPA 92B; NFPA 101; NFPA 105; International Building Code (IBC)
UL Listing:
R13317
Fire Resistance Rating:
1½ hours or 3 hours
Fire Closure Temperature Options:
165°F; 212°F; 350°F
Copyright Holder:
Greenheck India Private Limited
Intended Use:
Preparation of written product specifications under CSI MasterFormat Division 23
Subject:
Combination fire smoke dampers with steel 3-V blades
Note:
Year
Topic:
Networking
Document Type:
Guide
Year:
2023
Region / City:
London
Topic:
Structural Analysis, Engineering, Composite Materials
Document Type:
Research Report
Organization / Institution:
Imperial College London
Author:
Imperial Eco-Marathon Team
Target Audience:
Engineers, Researchers, Students in Engineering
Period of Validity:
Not specified
Approval Date:
Not specified
Modification Date:
Not specified
Year:
2021
Region / City:
Online
Topic:
MBS User Services, Domain Model
Document Type:
Technical Report
Organization / Institution:
3GPP
Author:
BBC, Ericsson LM
Target Audience:
Technical professionals in the field of telecommunications
Effective Period:
December 2, 2021 – February 3, 2022
Approval Date:
2021-12-02
Revision Date:
2021-12-02
Change Request Number:
S4aI211262
Work Item Code:
5MBUSA
Category:
B
Release:
Rel-17
Reason for Change:
Improve documentation of domain model
Summary of Change:
Text describing the MBS User Services domain model and baseline parameters
Clauses Affected:
4.5
Other Specifications Affected:
Yes, Test Specifications, O&M Specifications
Description:
Document that defines the domain model for MBS User Services, detailing the interactions and configurations for multicast and broadcast communication services in mobile networks.
Year:
2026
Region / City:
Global
Subject:
Static management program, system administration, device configuration
Document type:
User guide, administrative manual
Organization / Institution:
SCS
Author:
Unknown
Target audience:
System administrators, facility managers, IT professionals
Validity period:
Ongoing
Approval date:
2026
Modification date:
N/A
Year:
2024
Region / City:
Swansea
Subject:
Healthcare, Medical Imaging, Cancer Treatment
Document Type:
Business Case
Institution / Organization:
NHS Wales
Author:
Neil Hartman, Adel Davies-Pugh, Heather Edwards
Target Audience:
Healthcare decision-makers, Welsh Government, NHS stakeholders
Period of Action:
2024-2026
Approval Date:
2024
Modification Date:
Not provided
Year:
2013
Region / City:
Not specified
Topic:
Square dance call equivalents
Document Type:
Guide
Organization / Institution:
Not specified
Author:
Bob Elling, Greg Malinowski
Target Audience:
Square dance enthusiasts
Period of validity:
Not specified
Date of approval:
Not specified
Date of changes:
Not specified
Note:
Year
Year:
2024
Region / City:
United States
Topic:
Stem Cell Therapy, Extracellular Vesicles, Brain Organoids
Document Type:
Dissertation
Institution:
Department of Chemical and Biomedical Engineering
Author:
Chang Liu
Advisor:
Dr. Yan Li
Target Audience:
Researchers in Regenerative Medicine, Neuroscience
Period of Validity:
N/A
Approval Date:
N/A
Modification Date:
N/A
Model number:
AC6
Question Classification:
Internet Settings
Part 1:
Connect the devices
Part 2:
Configure your computer
Part 3:
Setup the router
Part 4:
Check whether you can access internet
Network Connection Icon:
Local Area Connection
Local Area Connection Properties:
Internet Protocol Version 4(TCP/IPv4)
Wireless password:
8 characters minimum
Login password:
5-32 characters
Connection Type:
Static IP
ISP network info:
Provided by ISP
Connection Status:
Connected
System Settings:
WAN settings
MAC Address:
Clone
Model:
FD-B Static Curtain Fire Dampers
Division:
23 – Heating, Ventilation, and Air Conditioning (HVAC)
Section Number:
233313 (Previously 15820)
Document Type:
Product Specification Guide
Manufacturer:
United Enertech
Manufacturer Address:
3005 South Hickory Street, Chattanooga, TN 37407
Applicable Standards:
UL 555; NFPA 90A; NFPA 90B; NFPA 101; AMCA 500-D; AMCA 511; IBC; CSFM
Fire Rating Options:
1½ hours; 3 hours
Release Temperature Options:
165 ºF (74 ºC); 212 ºF (100 ºC)
Mounting Orientation:
Vertical and/or Horizontal
Warranty Period:
5 years
Application:
Static HVAC duct penetrations through fire-resistance-rated barriers
Execution Requirements:
Examination, Installation, Handling, Delivery, Storage