№ lp_1_2_02087
File format: docx
Character count: 11343
File size: 25 KB
This document provides detailed specifications for ultra-low leakage control dampers used in HVAC systems, including material requirements, performance standards, and installation guidelines.
Year:
2015
Region / City:
Kansas City, Missouri
Subject:
HVAC systems, dampers, air control devices
Document Type:
Product specification
Organization / Institution:
Ruskin Company
Author:
Ruskin Company
Target Audience:
Specifiers, engineers, and HVAC system designers
Period of validity:
Not specified
Approval Date:
Not specified
Date of amendments:
Not specified
Price: 8 / 10 USD
The file will be delivered to the email address provided at checkout within 12 hours.
The file will be delivered to the email address provided at checkout within 12 hours.
Don’t have cryptocurrency yet?
You can still complete your purchase in a few minutes:- Buy Crypto in a trusted app (Coinbase, Kraken, Cash App or any similar service).
- In the app, tap Send.
- Select network, paste our wallet address.
- Send the exact amount shown above.
The final amount may vary slightly depending on the payment method.
The file will be sent to the email address provided at checkout within 24 hours.
The product description is provided for reference. Actual content and formatting may differ slightly.
Year:
2021
Region / city:
International
Topic:
Machine learning, Cybernetics, Multi-objective optimization
Document type:
Journal article
Institution:
International Journal of Machine Learning and Cybernetics
Author:
Li, Y., Li, H., Wang, B., Hu, C., Zhang, L., Chen, J., Mi, J., Xie, B., Karagoz, G.N., Yazici, A., Dokeroglu, T., Lin, X., Qin, F., Peng, Y., Ji, H., Wu, G., Wang, G., Chan, P.P.K., He, Z., Hu, X., Liu, S., Nie, W., Gao, D., del Río, A.H., Aranguren, I., Oliva, D., Li, B., Xu, Z., Zhang, Y., Laiadi, O., Ouamane, A., Benakcha, A., Wang, Q., Zhao, H., Hu, Z., Li, Z., He, Y., Li, Y., Yuan, X., Liebelt, M.J., Shi, P., Perrusquía, A., Yu, W., Li, X., Li, W., Li, J., Huang, J., Xie, Z., Cao, W., Ming, Z., Zhang, C., Zuo, W., Yin, A.
Target audience:
Researchers, Academics, Machine Learning Practitioners
Period of validity:
January - February 2021
Approval date:
January 2021
Modification date:
February 2021
Year:
2026
Region / City:
New York State
Subject:
Diesel Fuel Procurement
Document Type:
Solicitation Attachment / Vendor Submission Form
Organization / Agency:
New York State Office of General Services (OGS)
Target Audience:
Prospective Vendors
Bid Reference Number:
23343
Submission Deadline:
See Key Events/Dates section of Solicitation
Requirements:
NYS Vendor Responsibility Questionnaire, NYS Workers’ Compensation and Disability Insurance coverage
Submission Method:
Email to [email protected]
Vendor Information:
Name, Address, City/State/Zip, NYS Vendor ID, Federal ID, Contact Email and Phone
Certification:
Vendor confirms intent to participate, acknowledges no obligation to submit a bid, and certifies included documents
Year:
2023
Region / City:
National Harbor, MD
Subject:
Aerospace, Cryogenics, Valve Design
Document Type:
Extended Abstract
Organization:
NASA Marshall Space Flight Center
Authors:
Cody L. Gilliland, Scott Kramer, James A. Richard, William F. Sadowski, Andrew N. Smith, Robert J. Walker
Target Audience:
Aerospace engineers, researchers in cryogenic propulsion systems
Period of Effectiveness:
Not specified
Approval Date:
Not specified
Date of Modifications:
Not specified
Year:
2018
Region / City:
Gaithersburg, MD
Topic:
Digital Forensics, Data Leakage
Document Type:
Case Study
Institution:
National Institute of Standards and Technology (NIST)
Author:
Not specified
Target Audience:
Digital Forensics professionals
Period of Validity:
Not specified
Approval Date:
July 23, 2018
Revision Date:
Not specified
Year:
2023
Region / City:
North America
Topic:
Air leakage testing, fenestration standards
Document Type:
Technical Committee Ballot
Organization / Institution:
National Fenestration Rating Council (NFRC)
Author:
David McDonald (Chair, Task Group), Dennis Anderson (Staff Liaison)
Target Audience:
Industry professionals, standards committees
Effective Period:
Not specified
Approval Date:
Not specified
Date of Changes:
2023
Year:
2026
Region / City:
N/A
Topic:
Fluid Control, Microvalves, Robotics
Document Type:
Research Article, Supplementary Information
Institution:
Tsinghua University
Author:
Jie An, Yang Jiang, Xiaojian Xiang, Tao Jiang, Kai Wang, Zewei Ren, Zipei Tan, Jinhui Nie
Target Audience:
Researchers in robotics, fluid control, and microvalve technology
Period of Validity:
N/A
Date of Approval:
N/A
Date of Modifications:
N/A
Supplementary Materials:
Yes
Experimental Details:
Yes
Impact Studies:
Yes
Simulation Results:
Yes
Year:
2016
Month:
March
Region:
California, United States
Subject:
Methane emissions reduction from natural gas systems
Document Type:
Staff report
Issuing Bodies:
California Public Utilities Commission; California Air Resources Board
Authors:
Elizabeth Scheehle; Winardi Setiawan; Charles Magee
Legal Basis:
Senate Bill 1371 (Leno, 2014); Order Instituting Rulemaking 15-01-008
Relevant Legislation:
Senate Bill 1371
Regulatory Proceeding:
Order Instituting Rulemaking 15-01-008
Adoption Context:
Rulemaking R.15-01-008
Responsible Agencies:
California Public Utilities Commission; California Air Resources Board
Contributing Division:
Safety and Enforcement Division
Scope:
Leak detection, quantification, prevention, and repair in transmission, distribution, and storage facilities
Workshop Date:
October 27, 2015
Working Group Period:
2015–2016
Disclaimer Status:
Not approved or disapproved by the Commission or the Board
Document Type:
Technical specification
Product Name:
Hydropad Leakage Make Up Reservoir
Model:
Hydropad Model
Manufacturer / Company:
Flexicraft Industries
Industry:
Industrial equipment and pressure vessel systems
Primary Components:
Carbon steel pressure vessel, heliarc welded diaphragm bellows separator, stainless steel inlet/outlet nozzle
Materials:
Carbon steel vessel; Type 316 stainless steel bellows and wetted components
Pressure Classes:
200 psig, 500 psig, 1000 psig, 3000 psig
Design Standard:
American Society of Mechanical Engineers unfired pressure vessel codes
Optional Certification:
ASME “U” stamp
Gas Medium:
Nitrogen gas pressurization around bellows exterior
Connection Types:
Weld ends, male NPT thread, ANSI flanges, or other factory-specified connections
Additional Equipment:
Gas charging valve, pressure gauge, lifting lugs, support legs
Application Context:
Leakage make-up reservoir for pressurized piping or fluid systems
Material Alternatives:
304 stainless steel or 316 stainless steel pressure vessel for corrosive environments
Year:
2021
Jurisdiction:
The Hague, Netherlands
Subject:
Civil law; environmental liability; oil contamination
Document type:
Court ruling
Court:
Court of Appeal The Hague, Civil Law Division
Cases:
200.126.804 (case a), 200.126.834 (case b)
Parties:
Fidelis Ayoro Oguru, Alali Efanga (deceased), Friends of the Earth Netherlands vs. Shell Petroleum N.V., The “Shell” Transport and Trading Company Limited, Royal Dutch Shell PLC, Shell Petroleum Development Company of Nigeria Ltd.
Lawyers:
Meester Ch. Samkalden, Meester J. de Bie Leuveling Tjeenk
Location of events:
Oruma, Bayelsa State, Nigeria
Related events:
Oil leakages in Goi (2004) and Ikot Ada Udo (2007)
Date of ruling:
29 January 2021
Legal topics:
Parent company liability, Nigerian law, decontamination, environmental claims, Rylands v Fletcher rule
Procedural history:
Appeals against District Court rulings of 30 January 2013, prior interlocutory rulings in 2015–2018
Year:
2022
Region / City:
United States
Subject:
Air Leakage Testing for Fenestration Products
Document Type:
Ballot
Organization / Institution:
National Fenestration Rating Council (NFRC)
Author:
Technical Committee, Air Leakage Subcommittee
Target Audience:
NFRC Members, Industry Professionals
Effective Period:
February 4, 2022 - February 24, 2022
Approval Date:
February 4, 2022
Amendment Date:
N/A
Year:
2015
Region / City:
Kansas City, Missouri
Theme:
HVAC Systems
Document Type:
Product Specification
Organization / Institution:
Ruskin Company
Author:
Ruskin Company
Target Audience:
Specifiers, HVAC engineers
Period of Validity:
Not specified
Approval Date:
Not specified
Amendment Date:
Not specified
Note:
Year
Model:
CB-601
Product Name:
Backdraft Dampers
Division:
23 – Heating, Ventilation, and Air Conditioning (HVAC)
Section Number:
233313 (Previously 15820)
Type of Operation:
Gravity operated or actuator operated
Manufacturer:
United Enertech
Manufacturer Address:
3005 South Hickory Street, Chattanooga, TN 37407
Manufacturer Phone:
(423) 698-7715
Standards Referenced:
AMCA 500-D; AMCA 511
Maximum Velocity:
4000 fpm (20.4 m/s)
Temperature Range:
-40°F to 200°F (-40°C to 93°C)
Differential Pressure Rating:
4.0 in. wg. (99.6 kPa)
Leakage Rating:
12 cfm/ft² @ 1 in. wg.
Frame Material:
Extruded aluminum
Blade Material:
Extruded aluminum
Seal Material:
Extruded vinyl
Mounting Orientation:
Vertical or horizontal
Warranty Period:
5 years
Factory Testing:
Cycle tested for proper operation
Applicable Systems:
HVAC duct systems
Related Sections:
233100 – HVAC Ducts and Casings; 230913.13 – Actuators and Operators
Model:
FD-B Static Curtain Fire Dampers
Division:
23 – Heating, Ventilation, and Air Conditioning (HVAC)
Section Number:
233313 (Previously 15820)
Document Type:
Product Specification Guide
Manufacturer:
United Enertech
Manufacturer Address:
3005 South Hickory Street, Chattanooga, TN 37407
Applicable Standards:
UL 555; NFPA 90A; NFPA 90B; NFPA 101; AMCA 500-D; AMCA 511; IBC; CSFM
Fire Rating Options:
1½ hours; 3 hours
Release Temperature Options:
165 ºF (74 ºC); 212 ºF (100 ºC)
Mounting Orientation:
Vertical and/or Horizontal
Warranty Period:
5 years
Application:
Static HVAC duct penetrations through fire-resistance-rated barriers
Execution Requirements:
Examination, Installation, Handling, Delivery, Storage
Division:
23 – Heating, Ventilation, and Air Conditioning (HVAC)
Section:
233313 (Previously 15820)
Product Name:
Backdraft Dampers
Model:
CB-600
Manufacturer:
United Enertech
Manufacturer Address:
3005 South Hickory Street, Chattanooga, TN 37407
Standards Referenced:
Air Movement and Control Association (AMCA 500-D, AMCA 511)
Applicable Systems:
HVAC systems up to 2800 fpm (14.2 m/s)
Temperature Range:
-40°F to 200°F (-40°C to 93°C)
Maximum Velocity:
2800 fpm (14.2 m/s)
Differential Pressure Rating:
3.0 in. wg. (0.74 kPa)
Leakage Rating:
8.7 cfm/ft² @ 1 in. wg.
Construction Material:
Extruded aluminum frame and blades
Blade Operation:
Gravity operated or actuator operated
Mounting Orientation:
Vertical or horizontal (upblast or downblast)
Actuator Options:
Electric 24VAC, 120VAC, 230VAC with open or closed fail position
Warranty Period:
5 years
Testing Requirements:
Pressure drop and leakage ratings in accordance with AMCA 500-D
Quality Control:
Factory cycled prior to shipment
Year:
NA
Region / City:
NA
Topic:
Seismic engineering, high-rise buildings
Document Type:
Research project report
Institution:
NA
Author:
NA
Target Audience:
Engineers, researchers in structural and seismic engineering
Period of validity:
NA
Approval Date:
NA
Date of revisions:
NA
Context:
Research on seismic protection systems for high-rise buildings using LRB isolators and VE dampers.
Document Type:
Product Specification Guide
Product Name:
Model FSD-200 Series Combination Fire Smoke Dampers
Manufacturer:
Greenheck India Private Limited
Address:
Off No. 541-542, Tower B3, Spaze I-Tech Park, Sector-49, Sohna Road, Gurgaon – 122018, Haryana, India
Facility Service Subgroup:
Division 23 HVAC (Previously Division 15)
Applicable Standards:
UL 555 (Seventh Edition); UL 555S (Fourth Edition); AMCA 500-D; AMCA 511; NFPA 80; NFPA 90A; NFPA 92A; NFPA 92B; NFPA 101; NFPA 105; International Building Code (IBC)
UL Listing:
R13317
Fire Resistance Rating:
1½ hours or 3 hours
Fire Closure Temperature Options:
165°F; 212°F; 350°F
Copyright Holder:
Greenheck India Private Limited
Intended Use:
Preparation of written product specifications under CSI MasterFormat Division 23
Subject:
Combination fire smoke dampers with steel 3-V blades
Year:
2023
Region / City:
Chattanooga, TN
Topic:
Fire Dampers, HVAC Systems
Document Type:
Product Specification
Organization:
United Enertech
Author:
Not specified
Target Audience:
Engineers, Contractors
Effective Period:
Not specified
Approval Date:
Not specified
Amendment Date:
Not specified