№ files_lp_4_process_1_21888
File format: docx
Character count: 9196
File size: 189 KB
This document is a safety data sheet for Cobalt (II) Nitrate Hexahydrate, detailing its chemical properties, handling procedures, hazards, and first-aid measures for exposure.
Year:
2023
Region / City:
Maharashtra, India
Subject:
Chemical Safety
Document Type:
Safety Data Sheet
Organization:
Oxford Lab Fine Chem LLP
Author:
Oxford Lab Fine Chem LLP
Target Audience:
Professionals in Chemical and Safety Industries
Period of Validity:
Not specified
Approval Date:
Not specified
Revision Date:
Not specified
Price: 8 / 10 USD
The file will be delivered to the email address provided at checkout within 12 hours.
The file will be delivered to the email address provided at checkout within 12 hours.
Don’t have cryptocurrency yet?
You can still complete your purchase in a few minutes:- Buy Crypto in a trusted app (Coinbase, Kraken, Cash App or any similar service).
- In the app, tap Send.
- Select network, paste our wallet address.
- Send the exact amount shown above.
The final amount may vary slightly depending on the payment method.
The file will be sent to the email address provided at checkout within 24 hours.
The product description is provided for reference. Actual content and formatting may differ slightly.
Year:
Not available
Region / City:
Mumbai, Maharashtra, INDIA
Topic:
Chemical Safety Data
Document Type:
Safety Data Sheet
Organization / Institution:
OXFORD LAB FINE CHEM LLP
Author:
Not available
Target Audience:
Industry professionals, lab personnel
Effective Period:
Not available
Approval Date:
Not available
Amendment Date:
Not available
Year:
Not specified
Region / city:
India
Theme:
Chemical Safety
Document type:
Material Safety Data Sheet
Organization / Institution:
OXFORD LAB FINE CHEM LLP
Author:
Not specified
Target audience:
Workers handling chemicals
Period of validity:
Not specified
Approval date:
Not specified
Date of amendments:
Not specified
Year:
2022
Organization:
Cobalt Credit Union
Location:
Bellevue, NE, US
Document type:
Account policy notice
Target audience:
Members with checking accounts
Coverage:
Standard Overdraft Courtesy Plan and optional ATM/debit card overdraft authorization
Contact:
402-292-8000 | 800-228-0392
Address for form submission:
7148 Towne Center Parkway, Papillion, NE, US
Revision date:
November 2022
Note:
Year
Subject:
Radiation Safety, Nuclear Physics
Document Type:
Technical Manual
Target Audience:
Radiation safety professionals, radiographers
Company:
Cobalt Digital
Product Name:
OG-PC-x86
Event:
NAB Show
Booth:
SL6505
Date:
March 30, 2018
Location:
Champaign, Ill.
Industry:
Broadcast television technology
Product Type:
Modular PC card for 2RU openGear frame
Platform:
openGear
Processor Architecture:
x86
Form Factor:
2RU openGear ecosystem
Supported Operating Systems:
Windows 7 Professional; Windows 10 IoT
Storage Options:
Single hard drive or up to three drives with RAID support; M.2 SSD (32GB, 64GB, 128GB)
Connectivity:
HDMI 1.4; DisplayPort 1.2; USB 2.0; USB 3.0; Dual 1GigE RJ-45 NICs; DB9 RS-232
Compatibility:
DashBoard-compatible; DashBoard Connect-enabled products
Intended Applications:
Broadcast system integration; OB production; middleware hosting; VOD file storage and forwarding
Executive Quoted:
Jesse Foster, Director of Product and Business Development
CEO:
Bob McAlpine
Agency Contact:
Wall Street Communications
Document type:
Scientific supporting information
Scientific field:
Inorganic chemistry; organometallic catalysis
Research topic:
Hydroformylation of 1-octene using a cobalt hydride complex
Related research article:
Hydroformylation of 1-Octene Mediated by the Cobalt Complex [CoH(dchpf)(CO)2]
Authors:
Alexander Marco Kluwer; Michael J. Krafft; Ingo Hartenbach; Bas de Bruin; Wolfgang Kaim
Affiliations:
InCatT B.V., Amsterdam; Universität Stuttgart, Institut für Anorganische Chemie; Van ’t Hoff Institute for Molecular Sciences, Universiteit van Amsterdam
Country:
Netherlands; Germany
Compounds studied:
[CoH(dchpf)(CO)2]; octacarbonyldicobalt; 1-octene
Experimental techniques:
1H-NMR spectroscopy; 31P-NMR spectroscopy; infrared spectroscopy; cyclic voltammetry; gas chromatography; X-ray crystallography
Instrumentation:
Bruker AC 250 NMR spectrometer; Nicolet 6700 FT-IR spectrometer; PAR 273 potentiostat; Shimadzu GC Ultra with ChirasilDex CB column; Nonius Kappa CCD diffractometer; AMTEC SPR16 parallel autoclave system
Catalytic system:
Cobalt complex [CoH(dchpf)(CO)2]
Reaction type:
Hydroformylation under syngas (CO/H2) atmosphere
Substrate:
1-octene
Solvent:
Toluene
Reaction atmosphere:
Nitrogen and syngas (CO/H2 = 1:1)
Experimental conditions:
Temperatures 100–170 °C; pressures 10–40 bar
Reaction time:
21 hours
Analytical data:
NMR spectra, IR spectra, electrochemical data, crystallographic parameters, gas-uptake curves
Crystallographic system:
Monoclinic, space group P21/c
Empirical formula of studied complex:
C36H52CoFeO2P2
Molecular weight:
693.50
Year:
Not specified
Region / city:
India
Theme:
Chemical Safety
Document type:
Material Safety Data Sheet
Organization / Institution:
OXFORD LAB FINE CHEM LLP
Author:
Not specified
Target audience:
Workers handling chemicals
Period of validity:
Not specified
Approval date:
Not specified
Date of amendments:
Not specified
Year:
Not available
Region / city:
Not available
Subject:
Chemical Safety
Document Type:
Material Safety Data Sheet
Organization:
OXFORD LAB FINE CHEM LLP
Author:
Not available
Target audience:
Chemical safety professionals, laboratory personnel
Effective period:
Not available
Approval date:
Not available
Modification date:
Not available
Note:
Year
Industry:
Real Estate
Document Type:
Announcement
Organization:
Iron Gate Collective
Author:
Craig Lauppe
Target Audience:
Real Estate Professionals, Property Owners, Homeowner Associations
Year:
2026
Region / city:
Not specified
Theme:
Coordination Chemistry
Document Type:
Research Paper
Institution:
Not specified
Author:
Not specified
Target audience:
Scientists, Chemists
Period of validity:
Not specified
Approval date:
Not specified
Date of modifications:
Not specified
Year:
2019
Region / City:
North Carolina
Subject:
Water Quality Testing, Nitrogen, Nitrate + Nitrite
Document Type:
Standard Operating Procedure (SOP) Checklist
Agency / Institution:
Laboratory
Author:
Not specified
Target Audience:
Laboratory Analysts
Effective Period:
Ongoing
Approval Date:
Not specified
Date of Changes:
Not specified
Note:
Year
Subject:
Nitrate Vulnerable Zones, Grassland Derogation
Document Type:
Application Form
Organization / Institution:
Rural Payments and Inspections Directorate
Year:
2004
Region / city:
Lusaka, Zambia
Theme:
Fertilizers, Standards, Agriculture
Document type:
Notification
Organization / institution:
Zambia Compulsory Standards Agency
Author:
Zambia Compulsory Standards Agency
Target audience:
Stakeholders in agriculture and fertilization industry
Period of validity:
Not specified
Date of approval:
Not specified
Date of amendments:
Not specified
Year:
2004
Region / city:
Lusaka, Zambia
Topic:
Fertilizer standards
Document type:
Notification
Organization / institution:
Zambia Compulsory Standards Agency (ZCSA)
Author:
Zambia Compulsory Standards Agency (ZCSA)
Target audience:
Relevant stakeholders in the fertilizer industry, consumers
Effective period:
To be determined
Approval date:
To be determined
Amendment date:
To be determined
Year:
2023
Region / City:
Scotland
Topic:
Nitrogen fertiliser, agricultural practices, environmental protection
Document Type:
Consultation Response Form
Organization / Institution:
The Scottish Government
Author:
The Scottish Government
Target Audience:
Individuals and organizations involved in agriculture and environmental policy
Period of Effect:
Ongoing consultation
Approval Date:
Not specified
Date of Changes:
Not specified
Document Number:
DOC353.53.30574.Oct20
Product Name:
EZ1000 Series Nitrate Analyzer
Manufacturer:
Hach
Type of Document:
Technical Specification
Subject:
Semi-continuous online monitoring of nitrate and nitrite in water
Analytical Method:
Colorimetric measurement at 546 nm using NEDD
Applicable Standards:
ASTM 4500-NO3-A; ASTM 4500-NO2-A
Measurement Range:
0.2 to 10 mg/L NO3-N; optional 0.1 to 5 mg/L NO2-N
Limit of Detection:
≤0.2 mg/L NO3-N; ≤0.1 mg/L NO2-N
Cycle Time:
10 minutes per parameter
Protection Class:
IP55 (cabinet); IP65 (panel PC)
Certifications:
CE compliant; UL certified
Operating Temperature:
10 to 30 °C ±4 °C
Relative Humidity:
5 to 95 %, non-condensing
Power Supply:
As specified in installation drawings
Weight:
25 kg (55 lb)
Warranty Period:
Two years (Europe); one year (other geographies) from date of shipment
Maintenance Requirements:
Monthly reagent refill and validation/calibration; quarterly pump tubing replacement; annual calibration and tubing, valve and piston replacement
Installation Requirements:
Wall mounting per drawings; sample flow 100–300 mL/min; maximum particle size 100 µm; turbidity <50 NTU
Note:
Year
Topic:
Water testing, Coliform, Nitrate, Fluoride, pH, Hardness
Document Type:
Instructional Guide
Organization:
Central District Health Department
Target Audience:
Residents with private water supplies, individuals testing water quality
Year:
2026
Region / City:
United States
Subject:
Drinking water safety
Document type:
Public water system notice
Issuing authority:
U.S. Environmental Protection Agency
Public water system name:
Not specified
Public water system ID:
Not specified
Contaminants addressed:
Nitrate
Maximum Contaminant Level (MCL) exceeded:
Yes
Potential health effects:
Methemoglobinemia (blue baby syndrome), respiratory issues in infants
Target audience:
Residents consuming the public water supply
Corrective action expected completion date:
Not specified
Date distributed:
Not specified
Contact information:
Not specified
Year:
2020
Brand:
Hach
Product:
EZ1000 Nitrate Analyser
Type of document:
Technical specification
Measurement method:
Colorimetric measurement at 546 nm using NEDD, conform with ASTM 4500-NO3-A
Measuring range:
0.2 - 10 mg/L NO₃-N, optional NO₂-N 0.1 - 5 mg/L
Precision:
Better than 3% full scale range for standard test solutions
Detection limit:
≤ 0.2 mg/L
Cycle time:
10 min
Automatic cleaning:
Yes
Calibration:
Automatic, 2-point; frequency freely programmable
Validation:
Automatic; frequency freely programmable
Ambient temperature:
10 - 30 °C ± 4 °C deviation at 5 - 95% relative humidity (non-condensing)
Power supply:
100 - 240 VAC, 50/60 Hz, max. 120 VA
Instrument air:
Dry and oil free according to ISA-S7.0.01-1996
Reagent storage:
10 - 30 °C
Sample requirements:
Max particle size 100 µm, 0.1 g/L, turbidity ≤ 50 NTU, flow rate 100 - 300 mL/min, temperature 10 - 30 °C
Outputs:
Analog 4-20 mA, optional digital RS232, Modbus TCP/IP, RS485
Alarm:
1 malfunction, 4 user-configurable, max 24 VDC/0.5 A, potential-free contacts
Protection class:
Analyser cabinet IP55, Panel PC IP66
Material:
Thermoform ABS, plexiglass door, galvanised steel wall, powder coated
Dimensions (H x W x D):
690 x 465 x 330 mm
Weight:
25 kg
Certifications:
CE compliant, UL certified
Scope of delivery:
Online analyser, optional accessories including microfiltration systems, stands, and manufacturer services