№ lp_2_1_02293
File format: docx
Character count: 3508
File size: 77 KB
Construction specification section defining materials, fabrication, installation, quality assurance, and warranty requirements for metal framed glass mirrors in building projects.
Section Number:
08 83 00
Section Title:
Mirrors (Metal Framed)
Specification Type:
Construction Specification
Related Sections:
Section 10 28 00 - Toilet, Bath and Laundry Accessories; Section 01 30 00 - Administrative Requirements; Section 01 60 00 - Product Requirements
Referenced Standards:
ANSI Z97.1 (2010); ASTM C1036-01 (2016); ASTM C1503-01; GANA Glazing Manual (2008); GANA Sealant Manual (2008); GANA (TIPS) Mirrors: Handle with Extreme Care (2011)
Subject:
Metal Framed Glass Mirrors
Manufacturer:
Precision Frameworks™
Manufacturer Address:
2500 Royal Place, Tucker, GA 30084
Contact Information:
Toll Free Tel 877-739-1169; Email [email protected]
; Web https:
//www.precisionframeworks.com/
Product Series:
Precision Frameworks 711 Series
Glass Type:
Silvered Flat Glass Mirror
Glass Thickness:
1/8” and 3/16”
Frame Material:
6063 Grade Aluminum
Frame Finish:
Anodized G - Gold
Warranty Period:
One Year
Execution Requirements:
Examination, Preparation, Installation, Field Quality Control, Protection
Substitutions:
Not Permitted
Price: 8 / 10 USD
The file will be delivered to the email address provided at checkout within 12 hours.
The file will be delivered to the email address provided at checkout within 12 hours.
Don’t have cryptocurrency yet?
You can still complete your purchase in a few minutes:- Buy Crypto in a trusted app (Coinbase, Kraken, Cash App or any similar service).
- In the app, tap Send.
- Select network, paste our wallet address.
- Send the exact amount shown above.
The final amount may vary slightly depending on the payment method.
The file will be sent to the email address provided at checkout within 24 hours.
The product description is provided for reference. Actual content and formatting may differ slightly.
Year:
2016
Region / City:
Tucker, GA
Topic:
Mirrors, Glass, Installation
Document Type:
Specification
Organization / Institution:
Precision Frameworks™
Author:
Not specified
Target Audience:
Contractors, Installers, Manufacturers
Period of Validity:
Not specified
Approval Date:
Not specified
Amendment Date:
Not specified
Year:
2024
Region / City:
Ekurhuleni
Topic:
Procurement / Disaster Emergency Management
Document Type:
Formal Quotation
Organization / Institution:
Department of Finance, Department of Emergency Management Services
Author:
H. Van Schalkwyk, Ms. Nthabiseng Nkoe
Target Audience:
Bidders for procurement
Effective Period:
2024
Approval Date:
1 March 2024
Amendment Date:
14 December 2023
Year:
2016
Region / City:
Tucker, GA
Topic:
Mirrors, Glass, Installation
Document Type:
Specification
Organization / Institution:
Precision Frameworks™
Author:
Not specified
Target Audience:
Contractors, Installers, Manufacturers
Period of Validity:
Not specified
Approval Date:
Not specified
Amendment Date:
Not specified
Manufacturer:
Greenlite Glass Systems Inc.
Product Name:
LITELAM Fire-rated Glass Floor System
Address:
2495 Davies Ave. Unit 55, Port Coquitlam, BC, Canada V3C 0B2
Telephone:
778-285-8530
Email:
[email protected]
Website:
www.greenliteglass.com
Industry Sector:
Building construction and architectural glazing
Document Type:
Technical specification section for construction projects
Specification Section:
SECTION 08640 / SECTION 08 88 53
System Type:
Metal framed structural glazed floor system
Primary Material:
Fire-rated laminated structural glass with steel framing
Related Products:
Specialty architectural glass products
Associated Manufacturer:
Saint-Gobain Glass
Applicable Standards:
ASTM E119, UL263, CAN ULC-S101, ASTM E1300-09a, ASTM E2751/E2751M-13, ASTM C1028, ASTM E2188, ASTM E546, ASTM E2189, ASTM D5957, SSPC SP 6, AAMA 800, AAMA 1503-1998
Fire Rating Performance:
Up to 90 minutes integrity, insulation, and load-bearing capability
Design Loads:
Live load 60–100 psf uniform; 300 psf concentrated load
Deflection Limit:
L/360 maximum span deflection
System Application:
Structural glass floor, ceiling, or skylight assemblies
Referenced Construction Sections:
Concrete structure, firestopping, joint sealers, glass types, painting
Required Submittals:
Product data sheets, shop drawings, structural calculations, test reports, certificates, samples, warranties
Installer Qualification:
Authorized installer with minimum three years of experience in fire-rated glazing systems
Manufacturer Experience Requirement:
Minimum three years documented production of fire-rated glazing systems
Year:
2024
Region / City:
United Kingdom
Subject:
Structural Integrity of Metal Components in Nuclear Industry
Document Type:
Technical Assessment Guide
Organization / Institution:
Office for Nuclear Regulation (ONR)
Author:
Inspector and Principal Inspector
Target Audience:
ONR Inspectors and Nuclear Industry Stakeholders
Effective Period:
2024–2026
Approval Date:
September 2024
Next Review Date:
April 2026
Year:
Not specified
Region / City:
Not specified
Topic:
Sheet Metal Design and Engineering Checklist
Document Type:
Checklist
Organization / Institution:
Not specified
Author:
Not specified
Target Audience:
Engineers, Suppliers
Period of validity:
Not specified
Approval Date:
Not specified
Amendment Date:
Not specified
Context:
A checklist for engineers to confirm essential items when preparing drawings for custom sheet metal, ensuring compliance with material, design, and manufacturing standards.
Note:
Year
Year:
2024
Region / City:
Jackson, MI
Subject:
Roofing Replacements
Document Type:
Request for Proposals (RFP)
Organization / Institution:
Jackson County Parks
Author:
Jackson County Parks
Target Audience:
Contractors, Roofing Companies
Period of Action:
2024
Approval Date:
1/19/2024
Date of Changes:
N/A
Authors:
M. P. Browne; C. O’Rourke; Nathan Wells; A. Mills
Affiliation:
School of Chemistry and Chemical Engineering, Queen’s University Belfast
Country:
United Kingdom
Contact email:
[email protected]
Keywords:
Electrochemistry; Sustainable chemistry; Catalysis; Water splitting
Document type:
Scientific research article
Research field:
Electrocatalysis and photoelectrochemistry
Synthesis method:
Adams method using molten sodium nitrate
Materials studied:
RuO2; Mn2O3; Co3O4; NiO
Electrochemical reactions:
Hydrogen evolution reaction; Oxygen evolution reaction
Electrolyte:
1 M NaOH
Electrode preparation:
Solvent-free pressed powder discs with PTFE binder
Energy source:
Silicon solar cell under AM 1.5 G illumination
Source type:
Experimental laboratory study reporting synthesis, characterization, and electrochemical performance of metal oxide catalysts for solar-driven water splitting.
Year:
2026
Region / city:
Australia
Subject:
Roofing systems and associated works
Document type:
Worksection Template / Technical specification
Organization / institution:
NATSPEC, FIELDERS Steel Roofing Pty Ltd
Intended audience:
Engineers, architects, construction companies
Standards referenced:
AS/NZS 1170.2 (2021), AS 4055 (2021), AS/NZS 3500.3 (2021), AS 2312.1 (2014), AS 4312 (2019), AS 1657 (2018), AS/NZS 1170.3 (2003)
Materials covered:
FIELDERS seamed sheet metal, COLORBOND® prepainted steel, roof plumbing, skylights, roof hatches, roof windows, roof ventilators
Environmental considerations:
Bushfire protection, snow load, green roof design, recycled content, corrosion resistance
Responsibilities:
Provide FIELDERS specialised sheet metal roofing system as documented
Design parameters:
Wind pressure, rainfall intensity, R-Value, U-Value
Related worksections:
0193, 0342, 0343, 0411, 0461, 0471, 0472, 0552, 0802, 0423, 0425, 0426, 0427, 0428, 0429, 0311p, 0341p, 0436p, 0437p
Year:
2025
Note:
Region / city
Topic:
Metal fabrication, safety, welding, technical standards
Document type:
Standards
Target audience:
Students, metal fabrication professionals
Effective period:
July 2025
Year:
Not specified
Region / City:
Not specified
Topic:
Metal composite materials, rain screen systems, and performance requirements
Document Type:
Specification
Organization / Institution:
Not specified
Author:
Not specified
Target Audience:
Contractors, builders, and engineers involved in construction
Validity Period:
Not specified
Approval Date:
Not specified
Modification Date:
Not specified
Year:
2019
Region / City:
Oakland, CA
Subject:
Architectural Metal Finishes
Document Type:
Specification
Organization:
Móz Designs, Inc.
Manufacturer:
Móz Designs, Inc.
Target Audience:
Architects, Contractors
Warranty:
Yes
Installation Instructions:
Included
Date of Approval:
September 10, 2019
Materials:
Aluminum, Stainless Steel
Thickness:
Various (from .040” to 3/16”)
Finish Options:
Polycoat Gloss, Polycoat Matte, Powder Coat
Custom Options:
Yes
Examination:
Required prior to installation
Humidity Range:
80% or lower
Storage Conditions:
Avoid direct sunlight and moisture
Product Literature:
Yes
Samples:
Required
Year:
2022
Region / City:
N/A
Subject:
Stage 2 Material Solutions
Type:
Learning and Assessment Plan
School:
N/A
Teacher(s):
N/A
Program variant code:
A-W
Credits:
20
Assessment Type 1:
Specialised Skills Tasks – 20%
Assessment Type 2:
Design Process and Product – 50%
Assessment Type 3:
Resources Study – 30%
Endorsement:
Approved by principal or delegate
Date:
N/A
Changes:
Yes, outlined in Addendum
Evaluation method:
Multimodal (4 minutes / 600 words)
Note:
Year
Subject:
Wall Panel Products
Document Type:
Specification Guide
Organ / Institution:
Kingspan Insulated Panels
Target Audience:
Specifiers, Design Professionals
Context:
Guide specification for insulated exterior wall panels composed of IPN QuadCore insulation between metal facings, designed to reduce installation time and provide high-efficiency insulating core, exterior weather barrier, and vapor barrier.
Year:
2020
Region / city:
United Kingdom
Theme:
Climate, Weather, Data, Animation
Document type:
Research Statement
Organization / Institution:
Not specified
Author:
Harry Meadows
Target audience:
Scholars, enthusiasts of climate data, animation, and technology
Period of validity:
Not specified
Approval date:
25th August, 2020
Date of modifications:
Not specified
Note:
Year