№ files_lp_3_process_7_049948
File format: docx
Character count: 3138
File size: 19 KB
This document provides technical specifications for the EZ1000 Free Cyanide Analyser, detailing its measurement method, range, precision, and operational requirements.
Year:
2020
Region / City:
N/A
Topic:
Analytical Instrumentation
Document Type:
Product Specification
Organization / Institution:
Hach
Author:
N/A
Target Audience:
Engineers, Technicians
Effective Period:
N/A
Approval Date:
N/A
Date of Changes:
N/A
Price: 8 / 10 USD
The file will be delivered to the email address provided at checkout within 12 hours.
The file will be delivered to the email address provided at checkout within 12 hours.
Don’t have cryptocurrency yet?
You can still complete your purchase in a few minutes:- Buy Crypto in a trusted app (Coinbase, Kraken, Cash App or any similar service).
- In the app, tap Send.
- Select network, paste our wallet address.
- Send the exact amount shown above.
The final amount may vary slightly depending on the payment method.
The file will be sent to the email address provided at checkout within 24 hours.
The product description is provided for reference. Actual content and formatting may differ slightly.
Year:
2020
Region / city:
Not specified
Topic:
Water quality analysis
Document type:
Technical specification
Organization / institution:
Hach
Author:
Not specified
Target audience:
Engineers, technicians
Effective period:
Not specified
Approval date:
Not specified
Amendment date:
Not specified
Year:
2021
Region / City:
Not specified
Topic:
Water analysis, Dissolved Manganese measurement
Document type:
Technical specification
Organization / Institution:
Hach
Author:
Not specified
Target audience:
Engineers, technical staff
Period of validity:
Not specified
Approval date:
January 2021
Modification date:
Not specified
Year:
2020
Brand:
Hach
Product:
EZ1000 Nitrate Analyser
Type of document:
Technical specification
Measurement method:
Colorimetric measurement at 546 nm using NEDD, conform with ASTM 4500-NO3-A
Measuring range:
0.2 - 10 mg/L NO₃-N, optional NO₂-N 0.1 - 5 mg/L
Precision:
Better than 3% full scale range for standard test solutions
Detection limit:
≤ 0.2 mg/L
Cycle time:
10 min
Automatic cleaning:
Yes
Calibration:
Automatic, 2-point; frequency freely programmable
Validation:
Automatic; frequency freely programmable
Ambient temperature:
10 - 30 °C ± 4 °C deviation at 5 - 95% relative humidity (non-condensing)
Power supply:
100 - 240 VAC, 50/60 Hz, max. 120 VA
Instrument air:
Dry and oil free according to ISA-S7.0.01-1996
Reagent storage:
10 - 30 °C
Sample requirements:
Max particle size 100 µm, 0.1 g/L, turbidity ≤ 50 NTU, flow rate 100 - 300 mL/min, temperature 10 - 30 °C
Outputs:
Analog 4-20 mA, optional digital RS232, Modbus TCP/IP, RS485
Alarm:
1 malfunction, 4 user-configurable, max 24 VDC/0.5 A, potential-free contacts
Protection class:
Analyser cabinet IP55, Panel PC IP66
Material:
Thermoform ABS, plexiglass door, galvanised steel wall, powder coated
Dimensions (H x W x D):
690 x 465 x 330 mm
Weight:
25 kg
Certifications:
CE compliant, UL certified
Scope of delivery:
Online analyser, optional accessories including microfiltration systems, stands, and manufacturer services
Year:
Not specified
Region / city:
Not specified
Topic:
Safety and handling of hydrogen cyanide and cyanide salts
Document type:
Standard Operating Procedure
Organization / institution:
Not specified
Author:
Not specified
Target audience:
Laboratory personnel
Validity period:
Not specified
Approval date:
Not specified
Modification date:
Not specified
Year:
2024
Region / City:
Flint Hill
Theme:
Fire Safety, Hazardous Materials
Document Type:
Standard Operating Guideline
Organization:
Flint Hill Fire Department
Author:
Fire Chief
Target Audience:
Firefighters, Emergency Responders
Period of Effectiveness:
Ongoing
Approval Date:
02/12/2024
Amendment Date:
N/A
Description:
A guideline for fire department personnel on hydrogen cyanide (HCN) monitoring during fire incidents to protect against respiratory and skin exposure to this toxic gas.
Year:
2012
Region / city:
New Zealand
Topic:
Chemistry / Environmental Impact
Document Type:
Internal Assessment Resource
Organization / Institution:
Ministry of Education, New Zealand
Author:
New Zealand Qualifications Authority (NZQA)
Target Audience:
Teachers, students (Chemistry Level 3)
Period of Validity:
2013 and onwards
Approval Date:
December 2012
Date of Last Revision:
None
Resource Reference:
Chemistry 3.3A
Assessment Standard:
Achievement Standard Chemistry 91389
Context/Setting:
Gold extraction using cyanide in a local community
Teacher Guidelines:
Includes details for valid and consistent assessment
Authenticity of Evidence:
Requires modification for authenticity and local relevance
Required Materials:
Internet access, printed resources if necessary
Additional Information:
None
Note:
Year
Topic:
Medical Diagnostics
Document Type:
Standard Operating Procedure (SOP)
Organization:
Siemens
Author:
Jane Mason
Target Audience:
Medical professionals
Period of Use:
Indefinite
Year:
2020
Region / city:
Not specified
Topic:
Water quality analysis
Document type:
Technical specification
Organization / institution:
Hach
Author:
Not specified
Target audience:
Engineers, technicians
Effective period:
Not specified
Approval date:
Not specified
Amendment date:
Not specified
Year:
2020
Region / city:
Not specified
Subject:
Analytical Instrumentation
Document type:
Specification
Organization / Institution:
Hach
Author:
Not specified
Target audience:
Engineers, technical personnel
Period of validity:
Not specified
Approval date:
July 20, 2020
Modification date:
Not specified
Year:
2021
Region / City:
Not specified
Topic:
Water analysis, Dissolved Manganese measurement
Document type:
Technical specification
Organization / Institution:
Hach
Author:
Not specified
Target audience:
Engineers, technical staff
Period of validity:
Not specified
Approval date:
January 2021
Modification date:
Not specified
Year:
2026
Region / City:
Global
Subject:
Water Quality Monitoring / Phosphate Measurement
Document Type:
Technical Specification
Organization / Institution:
Hach
Product:
NP6000sc Online Phosphate Analyser
Measurement Method:
Molybdovanadate yellow colorimetric method
Measuring Range:
0.015 - 75 mg/L PO4-P depending on model
Detection Limit:
0.015 - 1 mg/L PO4-P depending on model
Accuracy:
2% of measured value + detection limit
Repeatability:
0.7 - 2% of measured value + detection limit
Channels:
1 or 2
Controller Compatibility:
Digital SC Controller
Power Supply:
115 VAC or 230 VAC
Operating Temperature:
-20 to 45 °C, 95% relative humidity, non-condensing
Storage Conditions:
-20 to 60 °C, 95% relative humidity, non-condensing
Enclosure Rating:
IP55, NEMA 3R UL50E
Flow Rate:
0.5 - 20.0 L/h
Sample Pressure:
Max 2.5 bar
Sample Temperature:
4 - 40 °C
Accessories Included:
Mounting kits, cables, doors, power supply options
Services:
Start-up support, operational training, maintenance agreements, external filtration recommendations
Year:
2020
Brand:
Hach
Product:
EZ1000 Nitrate Analyser
Type of document:
Technical specification
Measurement method:
Colorimetric measurement at 546 nm using NEDD, conform with ASTM 4500-NO3-A
Measuring range:
0.2 - 10 mg/L NO₃-N, optional NO₂-N 0.1 - 5 mg/L
Precision:
Better than 3% full scale range for standard test solutions
Detection limit:
≤ 0.2 mg/L
Cycle time:
10 min
Automatic cleaning:
Yes
Calibration:
Automatic, 2-point; frequency freely programmable
Validation:
Automatic; frequency freely programmable
Ambient temperature:
10 - 30 °C ± 4 °C deviation at 5 - 95% relative humidity (non-condensing)
Power supply:
100 - 240 VAC, 50/60 Hz, max. 120 VA
Instrument air:
Dry and oil free according to ISA-S7.0.01-1996
Reagent storage:
10 - 30 °C
Sample requirements:
Max particle size 100 µm, 0.1 g/L, turbidity ≤ 50 NTU, flow rate 100 - 300 mL/min, temperature 10 - 30 °C
Outputs:
Analog 4-20 mA, optional digital RS232, Modbus TCP/IP, RS485
Alarm:
1 malfunction, 4 user-configurable, max 24 VDC/0.5 A, potential-free contacts
Protection class:
Analyser cabinet IP55, Panel PC IP66
Material:
Thermoform ABS, plexiglass door, galvanised steel wall, powder coated
Dimensions (H x W x D):
690 x 465 x 330 mm
Weight:
25 kg
Certifications:
CE compliant, UL certified
Scope of delivery:
Online analyser, optional accessories including microfiltration systems, stands, and manufacturer services
Year:
2026
Region / City:
Not specified
Topic:
Medical Equipment / Chemistry Analysis
Document Type:
User Manual
Institution / Organization:
Not specified
Author:
Not specified
Target Audience:
Healthcare professionals, Laboratory technicians
Period of Validity:
Not specified
Approval Date:
Not specified
Date of Changes:
Not specified
Year:
2026
Organization:
Abbott Laboratories
Document Type:
Competency Assessment Form
Region / Location:
Not specified
Intended Audience:
Laboratory and clinical staff using the Afinion 2 analyser
Subject:
HbA1c measurement and analyser operation
Method:
Boronate affinity assay
Assessment Date:
Not specified
Trainer / Assessor:
Senior nurse or manufacturer trainer
Sample Type:
Finger prick whole blood
Quality Control:
Preparation and analysis of QC specimens included