№ files_lp_4_process_2_73842
File format: docx
Character count: 8035
File size: 40 KB
This document is a technical specification outlining the installation requirements for preformed metal siding, soffit, and fascia, including material standards, product data, and installation procedures.
Year:
Not specified
Region / city:
Not specified
Topic:
Construction, Metal Siding Installation
Document Type:
Technical Specification
Organization / Institution:
Not specified
Author:
Not specified
Target audience:
Contractors, architects, construction professionals
Period of validity:
Not specified
Date of approval:
Not specified
Date of changes:
Not specified
Standards referenced:
ASTM, Canadian General Standards Board, LEED Canada, CSA, Environmental Choice Program, SCAQMD
Price: 8 / 10 USD
The file will be delivered to the email address provided at checkout within 12 hours.
The file will be delivered to the email address provided at checkout within 12 hours.
Don’t have cryptocurrency yet?
You can still complete your purchase in a few minutes:- Buy Crypto in a trusted app (Coinbase, Kraken, Cash App or any similar service).
- In the app, tap Send.
- Select network, paste our wallet address.
- Send the exact amount shown above.
The final amount may vary slightly depending on the payment method.
The file will be sent to the email address provided at checkout within 24 hours.
The product description is provided for reference. Actual content and formatting may differ slightly.
Year:
2023
Region:
China
Subject:
Male rectal cancer, laparoscopic surgery, postoperative urogenital function
Document Type:
Clinical trial protocol
Organization:
Sun Yat-sen University, Multiple affiliated hospitals
Author:
Research Team
Target Audience:
Medical professionals, researchers, clinicians
Period of Action:
Not specified
Approval Date:
Not specified
Date of Changes:
Not specified
Year:
2023
Region / City:
Arden, North Carolina
Topic:
Roofing Systems
Document Type:
Guide Specification
Organization / Institution:
Hickman Edge Systems
Author:
Hickman Edge Systems
Target Audience:
Architects, Contractors
Effective Period:
Not specified
Approval Date:
Not specified
Modification Date:
Not specified
Organization:
Hickman Edge Systems
Address:
4 Commerce Way, Arden, North Carolina 28704
Country:
United States
Phone:
828-676-1700
Website:
HickmanEdgeSystems.com
Email:
[email protected]
Document Type:
Guide specification
Specification Format:
Construction Specifications Institute (CSI) 3-Part Format
MasterFormat Section:
07 71 19.03
Subject:
Manufactured fascia systems with flashing for roofing edges
Related System:
Low-slope roofing edge systems
Reference Standards:
ANSI/SPRI/FM 4435/ES-1 – Wind Design Standard for Edge Systems Used with Low Slope Roofing Systems
Industry Organization Reference:
FM Global; SPRI (Single Ply Roofing Industry)
Manufacturer:
Hickman Edge Systems
Product System:
“Drip Edge” Fascia System
Primary Materials:
Aluminum fascia covers; galvanized steel cleats
Material Thickness Options:
0.040", 0.050", 0.063" aluminum; 24 ga. or 22 ga. galvanized steel
Typical Applications:
Single-ply roofing systems
Wind Warranty Options:
Up to 215 mph lifetime wind warranty or 90 mph 10-year wind warranty
Finish Warranty:
Limited 30-year warranty for prefinished coil-coated steel and aluminum with Kynar 500 colors
Installer Qualification Requirement:
Minimum 5 years of fascia installation experience
Manufacturer Qualification Requirement:
Minimum 15 years manufacturing fascia systems
Sample Requirement:
Minimum 6-inch fascia sample and color chip set
Submittal Types:
Product data, shop drawings, samples, certifications, project references, warranty documentation
Referenced Project Documentation:
Drawings, Division 01 specifications, and roofing sections
Year:
2023
Region / City:
Minneapolis, MN
Theme:
Construction, Building Materials
Document Type:
Specification
Organization / Institution:
Nystrom
Author:
Nystrom
Target Audience:
Contractors, Engineers, Architects
Period of Action:
Not specified
Approval Date:
Not specified
Date of Changes:
Not specified
Context:
This document is a technical specification for preformed foam joint seals used in construction projects, detailing material requirements, installation methods, and quality assurance standards.
Effective:
April 1, 2012
Revised:
April 1, 2016
Revised Article 780.02:
Preformed Plastic Pavement Markings, Type B and Type C
Revised Article 780.07(a):
Inlaid Application on Freshly Placed HMA
Revised Article 780.11:
Inspection and Performance Period
Revised Article 780.13:
Basis of Payment
Date of Publication:
January 8, 2016
Note:
Approval by Bureau of Materials and Physical Research
Year:
2026
Region / City:
Not specified
Theme:
Construction, Roofing
Document Type:
Technical Specification
Organization / Institution:
ARTSPAN INC., WESTMAN STEEL, U-BUILD STEEL BUILDINGS, BEHLEN INDUSTRIES
Author:
Not specified
Target Audience:
Contractors, Architects, Engineers
Period of Validity:
Not specified
Approval Date:
Not specified
Date of Changes:
Not specified
Reference Standards:
ASTM, NFPA, ULC, CSA, CSSBI
Quality Assurance:
Structural design in accordance with CSA-S136
Coordination:
Coordinate with other work related to vapour retarder and air barrier system
Pre-Installation Meeting:
Convene one week before starting work
Submission Requirements:
Shop Drawings, Product Data, Installation Data, Design Data, Maintenance Data
Contextual Description:
This technical specification outlines the requirements for insulated metal standing seam roof panels, including materials, performance standards, and installation procedures, with specific references to applicable standards and submittal requirements.
Year:
2018
Region / City:
United States, Alaska, Hawaii, Caribbean
Subject:
Metal Panel Systems, Architectural Metals
Document Type:
Specification Guide
Organization:
Sheffield Metals International
Author:
Sheffield Metals International
Target Audience:
Architects, Designers, Engineers
Validity Period:
Not specified
Approval Date:
2018
Revision Date:
Not specified
Related Requirements:
Division 01 Section "Sustainable Design Requirements", Division 07 Sections "Metal Wall Panels", "Joint Sealants", "Soffit Panels"
References:
AAMA 621, AAMA 809.2, AAMA 2605, ASTM A 653, ASTM A 792/A 792M, ASTM B 209, ASTM E 84, ASTM E 331, ASTM E 1592
Description:
Detailed specification for the installation of Sheffield Metals International’s 1.0" flush wall and soffit panels over open framing, with related metal trim and accessories, focusing on materials, manufacturer qualifications, and technical requirements for architectural projects.
Note:
Year
Year:
2026
Region / City:
North America, Australia, New Zealand, Asia, Europe
Topic:
Fiber Cement Siding, Building Products, Construction
Document Type:
Specification
Organization:
James Hardie Building Products, Inc.
Author:
James Hardie Building Products, Inc.
Target Audience:
Construction professionals, architects, and installers
Effective Period:
2026 onwards
Approval Date:
2026
Revision Date:
N/A
Year:
2023
Region / City:
North America / Edmonton, Alberta, Canada
Subject:
Construction Materials – Soffit Panels
Document Type:
Technical Specification
Organization / Institution:
Sagiper North America Inc.
Author:
Sagiper North America Inc.
Target Audience:
Architects, Contractors, Installers
Code Compliance:
Florida Building Code (FBC FL41603)
Materials:
Plastic panels (PVC), accessories, trim
Testing Standards:
ASTM C158, ASTM C653, ASTM D374, ASTM D696, ASTM D2244, ASTM D2457, ASTM D4477, ASTM E1753, ASTM G155, DIN EN 53495
Related Sections:
Carpentry, Board Insulation, Sheet Metal, Joint Sealants, Gypsum Boards, Ceilings, Fire Suppression, Electrical
Warranty:
Manufacturer’s standard limited warranty
Delivery & Storage:
In accordance with manufacturer recommendations
Installation Requirements:
Minimum 3 years installer experience, coordination with construction schedule, field measurements required