№ lp_1_2_28873
File format: docx
Character count: 15649
File size: 172 KB
The document provides specifications for high-performance horizontal fan coil units, including design, construction, and performance requirements for HVAC systems.
Year:
Not specified
Region / city:
Not specified
Subject:
Heating, Ventilating, and Air Conditioning
Document Type:
Specification
Organization / Institution:
Price Industries, Inc.
Author:
Not specified
Target Audience:
Engineers, Contractors, HVAC professionals
Period of validity:
Not specified
Approval date:
Not specified
Date of amendments:
Not specified
Price: 8 / 10 USD
The file will be delivered to the email address provided at checkout within 12 hours.
The file will be delivered to the email address provided at checkout within 12 hours.
Don’t have cryptocurrency yet?
You can still complete your purchase in a few minutes:- Buy Crypto in a trusted app (Coinbase, Kraken, Cash App or any similar service).
- In the app, tap Send.
- Select network, paste our wallet address.
- Send the exact amount shown above.
The final amount may vary slightly depending on the payment method.
The file will be sent to the email address provided at checkout within 24 hours.
The product description is provided for reference. Actual content and formatting may differ slightly.
Note:
Year
Topic:
Mechanical Systems, HVAC
Document Type:
Technical Specification
Agency / Organization:
International Environmental Corporation
Target Audience:
Engineers, Contractors
Note:
Year
Subject:
Mechanical Specifications
Document Type:
Technical Specification
Organization / Institution:
International Environmental Corporation
Contextual Description:
Technical specification for horizontal fan coil units and related components, detailing product design, materials, certification, and system configuration requirements.
Year:
2019
Region / City:
United States
Topic:
HVAC Equipment
Document Type:
Technical Specification
Organization:
International Environmental Corporation
Author:
International Environmental Corporation
Target Audience:
Engineers, HVAC professionals
Effective Period:
Ongoing
Approval Date:
2019
Modification Date:
N/A
Project Name:
MGY Concealed Mega Modular Hi-Rise
Submitting Contractor:
Not specified
Engineer:
Not specified
Manufacturer’s Rep:
Not specified
Manufacturer:
International Environmental Corporation
System Type:
2-pipe / 4-pipe fan coil configurations, R-410a DX options
Standards:
AHRI 440-2019, ETL, ISO 9001:2015, ISO 14001:2015, NFPA-90A, GREENGUARD IAQ
Unit Components:
Coil, fan, motor, drain pan, wiring, piping, controls
Insulation:
Fiberglass or closed-cell options
Air Filters:
Non-woven synthetic or pleated MERV 8
Date of Certification:
Not specified
Safety Compliance:
ANSI/UL Standard 1995, CAN/CSA C22.2 No. 236
Year:
2024
Region / city:
Oklahoma City, OK
Theme:
Mechanical engineering, HVAC systems
Document type:
Technical specifications
Organization:
International Environmental Corporation (IEC®)
Author:
Not specified
Target audience:
Engineers, contractors, HVAC professionals
Effective period:
Not specified
Approval date:
Not specified
Modification date:
Not specified
Note:
Year
Topic:
Mechanical Specifications
Document Type:
Technical Specification
Organization / Institution:
International Environmental Corporation
Target Audience:
Engineers, Contractors, Manufacturers
Note:
Year
Document Type:
Letter of Indemnity
Subject:
Heavy weight cargo / steel coil shipment
Addressee:
EVERGREEN LINE (Evergreen Marine Corp. (Taiwan) Ltd.; Italia Marittima S.p.A.; Evergreen Marine (UK) Ltd.; Evergreen Marine (Hong Kong) Limited; Evergreen Marine (Asia) Pte. Ltd.; Evergreen Marine (Singapore) Pte. Ltd.)
Booking No. or B/L No.:
_________________________
Container No.:
_________________________
Vessel Voyage:
_________________________
Port of Loading (POL):
_________________________
Port of Discharge (POD):
_________________________
Commodity:
_________________________
Obligations:
Proper loading, stuffing, securing and lashing of cargo
Liability:
Indemnification for container/equipment damage and consequential losses
Compensation Terms:
Payment of repair costs or replacement value upon first written demand
Acceptance of Repair Costs:
Based on Estimate Repairs Forms issued by carrier’s depots/company
Acceptance of Replacement Value:
Based on Depreciated Value issued by carrier
Execution:
Name, Signature, Date (Day/Month/Year)
Company Details:
Company Name, Official Stamp, Address
Organization:
Coil Company
Document Type:
Technical manual
Equipment Type:
Direct Drive Fan Coil Units
Application:
Air handling equipment installation and service
Address:
P.O. Box 956, Paoli, PA 19301, United States
Phone:
(800) 523-7590; (610) 251-0257
Manufacturer:
Coil Company
Covered Equipment:
Horizontal and vertical fan coil units
Topics:
installation procedures, safety practices, equipment handling, inspection, and maintenance
Safety Guidance:
mechanical equipment handling and operation precautions
Storage Conditions:
dry indoor storage in original packaging until installation
Testing Guidance:
pressure testing with inert fluids or gases such as water or dry nitrogen
Warranty Conditions:
valid only with proper inspection, installation, operation, and periodic maintenance
Return Procedure:
factory authorization and return authorization number required for equipment returns
Year:
2026
Institution:
Technocrats Institute of Technology, Bhopal
Authors:
Umesh Kumar Sen, Sanjeev Yadav
Document Type:
Research Paper
Field:
Mechanical Engineering / Heat Transfer
Keywords:
Helical Coil, Heat Exchanger, CFD Analysis, Baffles, Mass Flow Rate, Thermal Performance
Fluids:
Water
Materials:
Aluminium
Geometry Parameters:
Tube diameters, Coil diameter, Pitch, Curvature ratios
Simulation Type:
CFD (Computational Fluid Dynamics)
Flow Arrangement:
Parallel flow
Baffle Types:
Rectangular, Semi-elliptical
Mass Flow Rate Analysis:
Hot fluid (0.14, 0.168, 0.196 kg/s), Cold fluid (0.084, 0.112, 0.14, 0.168 kg/s)
Year:
2005
Location:
Trichy, Tamilnadu, India
Field:
Mechanical Engineering / Thermal Systems
Document Type:
Research Paper
Institution:
CARE Group of Institutions
Authors:
S. Palanisamy, R. Naveenkumar
Target Audience:
Engineering students, researchers, industry professionals
Experimental Focus:
Helical coil heat exchanger under counter flow conditions for water-water and water-glycol combinations
Materials Used:
Copper (coil), Stainless steel SAE 304 (shell)
Measurements:
Temperature, flow rate, heat transfer coefficients
Key Components:
Helical coil, shell, pump, heater, thermocouples
Methodology:
Experimental design and analysis
Year:
2024
Division:
23 – Heating, Ventilating, and Air Conditioning
Section:
23 36 16 – Variable Air Volume Units
Type of Document:
Technical Specification
Manufacturer:
Price Industries, Inc.
Model:
LFT-EC
Standards Referenced:
ASHRAE 62.1, ASHRAE 70, IEC 60335, NFPA 70A, RoHS 3, UL 900, UL 2021
Target Audience:
Engineers, HVAC Contractors, Installers
Warranty:
18 months from date of shipment
Components:
Linear fan terminal, electric coil, plenum, modular connectors, air grilles
Pre-installation Requirements:
Mandatory meeting, sequencing of utility connections
Submittals Required:
Product data, shop drawings, coordination drawings, operation and maintenance data
Performance Metrics:
Airflow volume, pressure drops, heating/cooling element performance, sound performance, throw
Construction Materials:
Minimum 20 gauge steel plenum, ETL certified components
Year:
2016
Jurisdiction:
Wales
Region:
River Towy, Carmarthenshire
Document type:
EIA consent decision
Legal basis:
Marine Works (Environmental Impact Assessment) Regulations 2007 (as amended)
Regulation:
Regulation 22
Project description:
Deposit of an underground electricity cable using Horizontal Directional Drill
Applicant:
Western Power Distribution Ltd
Marine licence application number:
CML1551
Associated development:
Brechfa Forest onshore windfarm
Competent authority:
Natural Resources Wales Marine Licensing Team
Environmental documentation:
Environmental Statement
Consultation period:
February–March 2016
European protected sites:
River Towy SAC; Carmarthen Bay and Estuaries SAC
Decision outcome:
EIA consent granted subject to conditions
Approval dates:
04/07/2016; 30 November 2016
Year:
2012
Region / City:
Morgan County, Georgia
Topic:
Legal procedure, DUI test evidence
Document type:
Court brief
Organ / Institution:
Superior Court of Morgan County, Georgia
Author:
N/A
Target Audience:
Legal professionals, court officials
Period of validity:
N/A
Approval date:
N/A
Date of changes:
N/A
Year:
2014
Region / City:
Beachwood, OH
Topic:
Waterproofing, Construction Materials
Document Type:
Guide Specification
Organization:
Tremco, Inc.
Author:
Tremco, Inc.
Target Audience:
Architects, Specifiers, Contractors
Duration:
Not specified
Approval Date:
Not specified
Revision Date:
Not specified
Note:
Year
Contextual description:
This document outlines the specifications for the installation, testing, and delivery of communications copper horizontal cabling as part of a larger structured cabling system.
Note:
Year
Subject:
Mechanical Specifications
Document Type:
Technical Specification
Organization / Institution:
International Environmental Corporation
Contextual Description:
Technical specification for horizontal fan coil units and related components, detailing product design, materials, certification, and system configuration requirements.
Year:
2026
Region / City:
United States / Deer Park, WA
Topic:
Construction, Wall Assembly Systems
Document Type:
Guide Specification
Organization / Institution:
Knight Wall Systems, Inc.
Author:
Not specified
Target Audience:
Specification writers, engineers, construction professionals
Effective Period:
Not specified
Approval Date:
Not specified
Modification Date:
Not specified
Contextual description:
Guide specification for a thermally broken rainscreen attachment system with details on components, design requirements, performance standards, and submittal procedures.
Note:
Year
Topic:
Storage Tank Specifications
Document Type:
Technical Specification
Organization / Institution:
Highland Tank & Mfg. Co.
Target Audience:
Installers, Engineers